feat: Auto-detection inverter paralleli con script dedicati
Build Docker Image for Raspberry Pi / build-and-push (push) Successful in 7m18s

- Modificato entrypoint.sh per rilevare automaticamente inverter paralleli
- Usa flag -p per parallel discovery (testa QPGS0-9)
- Script mqtt-push-parallel.sh per pubblicare dati di ogni inverter
- Script mqtt-init-parallel.sh per discovery topics (ogni 10 min)
- Naming: voltronic_inv1, voltronic_inv2, ecc.
- Fallback automatico a single-mode se PARALLEL_COUNT=0

Nota: Il parallel discovery richiede che inverter supportino comandi QPGS
This commit is contained in:
Pi Developer
2026-02-02 23:24:49 +01:00
parent 53899b0fac
commit dc5bd07438
2 changed files with 117 additions and 5 deletions
+27 -5
View File
@@ -235,16 +235,38 @@ if [ "$NEED_DISCOVERY" = "true" ]; then
fi
echo ""
echo "=== Starting MQTT Bridge Services ==="
echo "=== Detecting Inverter Configuration ==="
echo ""
# Wait a bit for the device to be ready
sleep 2
# Init the mqtt server for the first time, then every 5 minutes
# Check for parallel inverters
PARALLEL_CHECK=$(/opt/inverter-cli/bin/inverter_poller -p 2>&1)
PARALLEL_COUNT=$(echo "$PARALLEL_CHECK" | grep "PARALLEL_COUNT=" | cut -d= -f2)
if [ ! -z "$PARALLEL_COUNT" ] && [ "$PARALLEL_COUNT" -gt 0 ]; then
echo "✓ Detected $PARALLEL_COUNT parallel inverter(s)"
echo " Using parallel mode scripts..."
USE_PARALLEL=true
MQTT_PUSH_SCRIPT="/opt/inverter-mqtt/mqtt-push-parallel.sh"
MQTT_INIT_SCRIPT="/opt/inverter-mqtt/mqtt-init-parallel.sh"
else
echo " Single inverter mode"
echo " Using standard scripts..."
USE_PARALLEL=false
MQTT_PUSH_SCRIPT="/opt/inverter-mqtt/mqtt-push.sh"
MQTT_INIT_SCRIPT="/opt/inverter-mqtt/mqtt-init.sh"
fi
echo ""
echo "=== Starting MQTT Bridge Services ==="
echo ""
# Init the mqtt server for the first time, then every 10 minutes (600 seconds)
# This will re-create the auto-created topics in the MQTT server if HA is restarted...
echo "Starting MQTT initialization service..."
watch -n 300 /opt/inverter-mqtt/mqtt-init.sh > /dev/null 2>&1 &
echo "Starting MQTT initialization service (every 10 minutes)..."
watch -n 600 "$MQTT_INIT_SCRIPT" > /dev/null 2>&1 &
# Run the MQTT Subscriber process in the background (so that way we can change the configuration on the inverter from home assistant)
echo "Starting MQTT subscriber for commands..."
@@ -257,4 +279,4 @@ echo "✓ All services started successfully!"
echo " Logs will appear below..."
echo ""
watch -n 30 /opt/inverter-mqtt/mqtt-push.sh > /dev/null 2>&1
watch -n 30 "$MQTT_PUSH_SCRIPT" > /dev/null 2>&1
+90
View File
@@ -0,0 +1,90 @@
#!/bin/bash
#
# MQTT Discovery for Parallel Inverters
# Registers Home Assistant auto-discovery topics for each parallel inverter
MQTT_CONFIG="/etc/inverter/mqtt.json"
INVERTER_BIN="/opt/inverter-cli/bin/inverter_poller"
MQTT_SERVER=$(jq -r '.server' "$MQTT_CONFIG")
MQTT_PORT=$(jq -r '.port' "$MQTT_CONFIG")
MQTT_TOPIC=$(jq -r '.topic' "$MQTT_CONFIG")
MQTT_DEVICENAME=$(jq -r '.devicename' "$MQTT_CONFIG")
MQTT_USERNAME=$(jq -r '.username' "$MQTT_CONFIG")
MQTT_PASSWORD=$(jq -r '.password' "$MQTT_CONFIG")
MQTT_CLIENTID=$(jq -r '.clientid' "$MQTT_CONFIG")
registerTopic () {
local inverter_id="$1"
local metric="$2"
local unit="$3"
local icon="$4"
local device_name="${MQTT_DEVICENAME}_inv${inverter_id}"
mosquitto_pub \
-h $MQTT_SERVER \
-p $MQTT_PORT \
-u "$MQTT_USERNAME" \
-P "$MQTT_PASSWORD" \
-i "${MQTT_CLIENTID}_init" \
-t "$MQTT_TOPIC/sensor/${device_name}_${metric}/config" \
-r \
-m "{
\"name\": \"${device_name}_${metric}\",
\"unit_of_measurement\": \"$unit\",
\"state_topic\": \"$MQTT_TOPIC/sensor/${device_name}_${metric}\",
\"icon\": \"mdi:$icon\",
\"unique_id\": \"${device_name}_${metric}\",
\"device\": {
\"identifiers\": [\"${device_name}\"],
\"name\": \"${device_name}\",
\"manufacturer\": \"Voltronic\",
\"model\": \"Parallel Inverter\"
}
}"
}
register_inverter_topics() {
local inverter_id="$1"
echo "Registering MQTT discovery topics for: ${MQTT_DEVICENAME}_inv${inverter_id}"
# Register all metrics for this inverter
registerTopic "$inverter_id" "serial" "" "identifier"
registerTopic "$inverter_id" "mode" "" "solar-power"
registerTopic "$inverter_id" "AC_grid_voltage" "V" "power-plug"
registerTopic "$inverter_id" "AC_grid_frequency" "Hz" "current-ac"
registerTopic "$inverter_id" "AC_out_voltage" "V" "power-plug"
registerTopic "$inverter_id" "AC_out_frequency" "Hz" "current-ac"
registerTopic "$inverter_id" "PV_in_voltage" "V" "solar-panel-large"
registerTopic "$inverter_id" "PV_in_current" "A" "solar-panel-large"
registerTopic "$inverter_id" "PV_in_watts" "W" "solar-panel-large"
registerTopic "$inverter_id" "Load_pct" "%" "brightness-percent"
registerTopic "$inverter_id" "Load_watt" "W" "chart-bell-curve"
registerTopic "$inverter_id" "Load_va" "VA" "chart-bell-curve"
registerTopic "$inverter_id" "Battery_capacity" "%" "battery-outline"
registerTopic "$inverter_id" "Battery_voltage" "V" "battery-outline"
registerTopic "$inverter_id" "Battery_charge_current" "A" "current-dc"
echo " ✓ Discovery topics registered"
}
# Discover parallel inverters
PARALLEL_DISCOVERY=$("$INVERTER_BIN" -p 2>&1)
PARALLEL_COUNT=$(echo "$PARALLEL_DISCOVERY" | grep "PARALLEL_COUNT=" | cut -d= -f2)
if [ -z "$PARALLEL_COUNT" ] || [ "$PARALLEL_COUNT" -eq 0 ]; then
echo "No parallel inverters found, falling back to standard init"
exec /opt/inverter-mqtt/mqtt-init.sh
exit 0
fi
echo "Found $PARALLEL_COUNT parallel inverters"
# Register topics for each inverter
for i in $(seq 1 $PARALLEL_COUNT); do
register_inverter_topics "$i"
done
echo "✓ All MQTT discovery topics registered for $PARALLEL_COUNT inverters"