Files
docker-voltronic-homeassistant/config/inverter.conf
T
Maxwell dfbb0ecc06 Add additional configurable parameters for buffers
Adds additional `qpiws`, `qmod` and `qpigs` parameters with default values used in source code, these values are currently based on the **skymax** inverter
2020-03-10 09:52:13 +02:00

42 lines
1.5 KiB
Plaintext

# Basic configuration options for the actual inverter polling process...
# The device to read from...
# Use: /dev/ttyS0 if you have a serial device,
# /dev/ttyUSB0 if a USB<>Serial,
# /dev/hidraw0 if you're connecting via the USB port on the inverter.
device=/dev/ttyUSB0
# How many times per hour is the program going to run...
# This is used to calculate the PV & Load Watt Hours between runs...
# If unsure, leave as default - it will run every minute...
# (120 = every 30 seconds)...
run_interval=120
# This allows you to modify the amperage in case the inverter is giving an incorrect
# reading compared to measurement tools. Normally this will remain '1'
amperage_factor=1.0
# This allows you to modify the wattage in case the inverter is giving an incorrect
# reading compared to measurement tools. Normally this will remain '1'
watt_factor=1.01
# The following settings allow you to modify runtime buffers.
# N.B. These values may not be applicable to all inverter types, as such you will
# need to run docker exec -it voltronic-mqtt bash -c '/opt/inverter-cli/bin/inverter_poller -d -1'
# or simply inverter_poller -d -1 to check for warnings or errors
# mentioned in https://github.com/ned-kelly/docker-voltronic-homeassistant/issues/5
# This allows you to modify the buffersize for the qpiri command
qpiri=97
# This allows you to modify the buffersize for the qpiws command
qpiws=36
# This allows you to modify the buffersize for the qmod command
qmod=5
# This allows you to modify the buffersize for the qpigs command
qpigs=110